Plant Cortex

Home / Industries / Power Generation

An outage is a hundred jobs that must not collide.

Most of a generating station's maintenance is compressed into planned outages. The risk is not any one job. It is two crews working on connected equipment without knowing about each other.

Start a pilot

A boiler feed pump seal starts to leak inside the outage window.

An illustrative night on this kind of floor, and what Plant Cortex does at each point.

  1. The finding

    During the outage walk-down, an operator finds the seal weeping. The window is fixed and the pump is on the critical path.

  2. The question

    The planner asks what the seal replacement involves. The answer cites the pump manual, lists the isolation points, and shows the seal kit on the shelf.

  3. The work

    The permit check shows another crew already has an active permit on the same pump discharge line, before either crew starts. A work order carries the parts reserved for this job.

  4. What stays

    Hours and parts are logged on the work order. The planned-versus-reactive picture updates, and the preventive plan for that pump now has a seal inspection step.

Where this floor gets hurt.

Simultaneous work on one system

Two permits on connected equipment is the classic outage hazard. A new permit is checked against open ones on the same equipment.

Parts that must be there on day one

Reserving stock against a work order means two jobs cannot count on the same last spare.

Preventive maintenance that drifts

Plans by calendar or by meter reading, with a working calendar that skips weekends and holidays.

Evidence for the audit

Who approved what, under which authority, with what signature, is held as a record, not rebuilt afterwards.

  • Boilers and burners
  • Steam and gas turbines
  • Feed and condensate pumps
  • Cooling towers
  • Generators and switchgear
  • Fuel handling

The questions this floor asks, and what comes back.

Examples of shape only. The real content comes from your own manuals and drawings.

What are the isolation points for the feed pump?

Comes back withIsolation steps from the pump manual with the page, ready to drop into a permit.

Which spares do we hold for the cooling tower fan gearbox?

Comes back withMatching stock lines, where-used links, and approved alternatives if you have recorded any.

The modules that matter most here.

Work orders

Hours, parts and checklists on one job, with reservations so parts are not double-booked.

PM plans

Calendar or meter based, with a working calendar and a compliance view.

Permits

Overlap check on the same equipment, approval by department or limit.

Maintenance KPIs

Backlog, planned versus reactive, schedule compliance, spend per machine.

Bring the manuals for one power generation unit.

A few real documents, a few weeks, and success criteria agreed up front.

Start a pilot